Balloon Catheters | Radiology Key

Dec 23, 2015· Balloon Catheters. Shawn N. Sarin, Wael E.A. Saad, David Nicholson, Ulku C. Turba, J. Fritz Angle, Klaus D. Hagspiel, Michael D. Dake and Alan H. Matsumoto Although Dotter and Judkins first described percutaneous transluminal angioplasty (PTA) in 1964, 1 use of the procedure did not gain momentum until 1976, when Gruentzig 2 described his double-lumen balloon …

PTA-Balloons

435 - 50 2 S PTA-Balloons General information. 40 Balloon Rated Burst Recommended Catalogue* Shaft Length OD x Length Pressure Sheath Fit Number (cm) (mm x cm) (atm) (F) 80 120 150 2 x 2 10 4 435-202 S L 2 x 4 10 4 435-204 S L X 2 x 6 10 5 435-206 S L 2 x 10 10 5 435-200 S L X 2.5 x 2 10 4 435-252 S L ...

METACROSS® RX (0.035") PTA Balloon Dilatation Catheter

First ever 0.035" PTA rapid exchange balloon catheter for peripheral use. Best-in-class pushability using an innovative catheter design 1. Excellent crossability with smallest balloon profile 1. Category-leading deflation time 1.

Atlas™ PTA Dilatation Catheter - BD

Balloon Length (cm) Shaft Length (cm) Nominal Pressure (atm) Rated Burst Pressure (atm) Sheath Size (F) Package. Units. AT75122. 12 mm x 20 mm Atlas™ Percutaneous Transluminal Angioplasty (PTA) Balloon with 75 cm Shaft Length and 7 French Sheath.

Ranger Paclitaxel-Coated PTA Balloon Catheter - P190019 | FDA

Nov 12, 2020· The Ranger Paclitaxel-Coated PTA Balloon Catheter (Ranger DCB) uses a drug-coated balloon to re-open blocked or narrowed arteries in the thigh and knee due to peripheral artery disease (PAD). The ...

Charger™ 0.035" Balloon Dilatation Catheter - Boston ...

The Charger PTA Balloon Dilatation Catheter shall only be used by physicians trained in the performance of percutaneous transluminal angioplasty. The Charger PTA Balloon Dilatation Catheter should be used with caution for procedures involving calcified lesions or synthetic vascular grafts due to the abrasive nature of these inflation sites.

Drug-Eluting Balloon in Peripheral Intervention for the ...

Dec 01, 2013· Thereafter, in patients randomized to PTA + BMS, a nitinol stent was implanted, whereas in the PEB + BMS group, further dilation of at least 120 s with a paclitaxel-coated balloon (In.Pact Admiral, Invatec/Medtronic, Santa Rosa, California), maintaining a vessel/balloon diameter ratio of 1:1 preceded nitinol stent implantation.

PTA Balloons for Peripheral Arterial Disease | Medtronic

A PTA balloon catheter has an inflatable "balloon" at its tip which is used during a minimally invasive catheterization procedure. This procedure is intended to enlarge a narrowed vessel opening. The deflated balloon is positioned at the narrowed space, inflated for a short period of time, and deflated again to be removed.

Association between post-balloon angioplasty dissection ...

Apr 29, 2021· Introduction. Although dissection events after uncoated balloon percutaneous transluminal angioplasty (PTA) are common, reports of the results are incomplete, especially regarding the increased use of drug-coated balloons (DCBs) in recent years. 1 –4 In accordance with our previous study, 5,6 we performed a sub-analysis to evaluate the outcome of …

Ultrascore™ Focused Force PTA balloon - BD

UltraScore™ Focused Force PTA Balloon is available on a .035″ and .014″platform, and is the lowest profile scoring balloon on the U.S. market. 2. Only 4F scoring balloon on the U.S. market 2. First .035″ scoring balloon commercially available on the U.S. market 2. Hydrophilic coating for optimized deliverability on .014" platform.

AngioSculpt PTA scoring balloon catheter 7 and 8 ...

The AngioSculpt PTA scoring balloon catheter in 7 and 8 millimeter diameter balloon sizes are ideally suited to treat the narrowing of the native or synthetic fistula. The product assists physicians with a difficult patient set, targeting lesions in the hemodialysis access that are resistant to standard balloon angioplasty.

Percutaneous transluminal coronary angioplasty (PTCA ...

May 10, 2019· The balloon is inflated for a few seconds to compress the blockage against the artery wall. Then it's deflated. The doctor may inflate the balloon a few more times, each time filling it a little more to widen the passage. This may then be …

0.035 PTA Balloons - Cordis

The CORDIS® 0.035 PTA Balloon Portfolio is comprised of the POWERFLEX® Pro PTA Catheter, POWERFLEX® P3 PTA Dilatation Catheter, POWERFLEX® Extreme PTA Dilatation Catheter, OPTA® Pro PTA Dilatation Catheter, and the MAXI LD® PTA Dilatation Catheter, which are workhorse solutions that deliver advanced crossing ability and remarkable versatility for …

SUMMARY OF SAFETY AND EFFECTIVENESS DATA (SSED)

Dec 30, 2014· Percutaneous Transluminal Angioplasty (PTA) Balloon Catheter Device Procode: ONU Applicant's Name and Address: Medtronic, Inc. 3576 Unocal Place Santa Rosa, CA 95403 USA Date(s) of Panel Recommendation: Not Applicable Premarket Approval Application: P140010 (PMA) Number: Date of FDA Notice of Approval: December 30, 2014

2021 Peripheral Interventions Vascular Coding Worksheet

37187 Percutaneous transluminal mechanical thrombectomy, vein(s) 37188 Percutaneous transluminal mechanical thrombectomy, vein(s); repeat treatment on subsequent day during course of thrombolytic therapy . Dialysis Circuit CPT® Abbreviated Description . x . 36901 Diagnostic evaluation 36902 PTA 36903 PTA + Stent

AngioSculpt XL PTA scoring balloon catheter | Philips ...

Designed specifically to address long, diffuse lesions commonly found in infrainguinal arteries, the AngioSculpt PTA scoring balloon catheter offers 360˚ of precise and effective dilatation. AngioSculpt's smart scoring balloon technology delivers a unique combination of controlled, effective dilatation and predictable device safety.

PTA Balloon Catheter Market To Surpass US$ 2,038.6 Million ...

22 · For instance, in December 2016, BrosMed announced the U.S FDA 510(k) clearance and launch of its Hermes NC 0.035 OTW PTA, Achilles NC 0.018 OTW PTA, and Castor NC 0.014 OTW PTA balloon dilatation catheter for the treatment of …

Boston Scientific Launches Charger™ PTA Balloon Catheter ...

The Charger PTA Balloon Catheter is Boston Scientific's third new peripheral balloon catheter introduced in 2011 and strengthens the Company's position as a global leader in peripheral angioplasty balloons. The Charger PTA Balloon Catheter is designed for post-stent dilatation as well as conventional balloon angioplasty to open blocked ...

Percutaneous Transluminal Angioplasty (PTA) Balloons I ...

NanoCross Elite 0.014" OTW PTA Balloon Catheter. Approach tight lesions with a low-profile, tapered tip when you use the NanoCross™ Elite 0.014" OTW PTA balloon catheter. The catheter's robust shaft design makes it easier to access, reach and treat distal lesions in the lower leg. Indications, Safety, and Warnings.

NCD - Percutaneous Transluminal Angioplasty (PTA) (20.7)

Jan 01, 2013· A. General. This procedure involves inserting a balloon catheter into a narrow or occluded blood vessel to recanalize and dilate the vessel by inflating the balloon. The objective of percutaneous transluminal angioplasty (PTA) is to improve the blood flow through the diseased segment of a vessel so that vessel patency is increased and ...

PTA Balloons – IGIASI S.A

May 23, 2016· PTA Balloon Catheter 0.018" "PowerCross". May 23, 2016. seris. PTA Balloons. Over-The-Wire .018″ PTA Ballons, low profile with tapered entry tip POWERCROSS. By Covidien – …

Summary of Safety and Effectivness (SSED)

percutaneous transluminal angioplasty, with a secondary action of inhibition of restenosis (caused by the proliferative response to the PTA) through the application of paclitaxel to the vessel wall. Additional details regarding the device can be found in the IN.PACT AV Paclitaxel-coated PTA Balloon

The world's largest RCT investigating use of MagicTouch ...

The world's largest RCT investigating use of MagicTouch PTA Sirolimus Coated balloon for peripheral artery disease kicks off to a flying start. Concept Medical Inc., focused on vascular intervention drug delivery devices, has announced the enrolment of the first patient in the SirPAD (Sirolimus in Peripheral Artery Disease) trial.

Drug Eluting Balloons PTA in Infra-popliteal Arteries in ...

Jul 15, 2015· Percutaneous transluminal angioplasty (PTA) of infra-popliteal arteries in patients suffering peripheral arterial occlusive disease (PAOD) provides good results in terms of limb salvage. During the last decade, drug eluting balloons (DEB) were found to be an effective tool for the treatment of atherosclerotic disease in several arterial districts.

Percutaneous Transluminal Angioplasty (PTA) (NCD 20.7)

This procedure involves inserting a balloon catheter into a occluded or narrow blood vessel to recanalize and dilate the vessel by inflating the balloon. The objective of PTA is to improve the blood flow through the diseased segment of a vessel so that ... NCD 20.7 Percutaneous Transluminal Angioplasty (PTA) ...

Athletis™ Ultra High Pressure Balloon - Boston Scientific

Athletis PTA Balloon's proprietary braided balloon design enables optimized deliverability and ultra-high pressures up to 40 ATM. The unique, non-compliant balloon design enables Athletis PTA Balloon to open to the stated diameter even in highly resistant lesions.

JADE® PTA Balloon Catheter | CSI360

2 · JADE ® PTA Balloon Catheter. Manufactured By. Strength and non-compliant precision without compromising deliverability. JADE PRODUCT BROCHURE. JADE ORDERING GUIDE. SAPPHIRE II PRO 1.0 OTW LEAFLET. Diverse Balloon Portfolio Only non-compliant balloon platform available in all three guidewire compatible systems on the US market*

PTA Balloon Catheter Market 2021 Global Share, Size ...

Aug 17, 2021· Aug 17, 2021 (The Expresswire) -- Global "PTA Balloon Catheter Market" (2021-2026) to its vast repository provides important statistics Centre's on worldwide significant makers of the PTA ...

MDT-2113 Drug-Eluting Balloon vs. Standard PTA for the ...

Sep 20, 2013· Iida O, Soga Y, Urasawa K, Saito S, Jaff MR, Wang H, Ookubo H, Yokoi H; MDT-2113 SFA Japan Investigators. Drug-Coated Balloon vs Standard Percutaneous Transluminal Angioplasty for the Treatment of Atherosclerotic Lesions in the Superficial Femoral and Proximal Popliteal Arteries: One-Year Results of the MDT-2113 SFA Japan Randomized Trial.

PTA Dilatation Catheter - C. R. Bard

enhanced PTA Dilatation Catheter TRACKABILITy The trackability test measures the peak force necessary to track a catheter through a tortuous anatomical model. 14 mm x 4 cm balloons: Atlas ® gold - 80 cm shaft, Atlas & XXL™ - 75 cm shaft 0

PTA Balloons - Cordis

The CORDIS® PTA Balloon Portfolio is comprised of 0.035 PTA Balloons, 0.018 PTA Balloons, 0.014 PTA Balloons, and Specialty PTA Balloons to help you treat routine and challenging cases. 0.035 PTA Balloons. The CORDIS® 0.035 PTA Balloon Portfolio offers everyday choices for treating diffuse and challenging lower extremity lesions.

Percutaneous Transluminal Angioplasty | Johns Hopkins Medicine

Percutaneous transluminal angioplasty is a minimally invasive procedure used to open a blocked artery. Your physician will follow this procedure: A small incision (cut) is made in the thigh, allowing access to the femoral artery. A guide wire is inserted into the artery. Under the guidance of X-ray video ( fluoroscopy ), the wire is threaded to ...

Medtronic's Chameleon PTA Balloon Catheter Studied for ...

Jun 23, 2021· June 23, 2021—Online in The Journal of Vascular Access (), Ari Kramer, MD; John Ross, MD; and Antonios P. Gasparis, MD, reported findings from a novel technique using a single device, the Chameleon percutaneous transluminal angioplasty (PTA) balloon catheter (Medtronic), to safely and efficiently perform percutaneous thrombectomy interventions.. The investigators noted that the Chameleon PTA ...

PTA Balloon Dilatation Catheter

Crosperio OTW is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. Crosperio OTW is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm). The shaft consists of an outer tube and an inner tube ( co-axial lumens structure).

Athletis™ PTA Balloon Catheter Indications, Safety and ...

Balloon Diameter (mm) Balloon Length (cm) Introducer Size (Fr) Recommended Guidewire (in) Rated Burst Pressures (ATM) Features Indication Page Ref PTA PTV BAV NuCLEUS-X™ 18 - 30 4 - 6 10 - 14 0.035 2 - 4 Waist formed in middle for accurate placement, braided inner lumen, dual indication • • p. 4